What is advantage of 2.5 sq mm 1.5 mm 6mm 25mm 16mm 2 core armoured cable?
The 16mm 2.5 sq mm 1.5 mm 6mm 25mm 2 core armoured cable mechanical are not only protective layer . But also can added to any structure of the cable to increase the mechanical strength of the cable. In order to improve corrosion resistance. The 2 core 10mm 4mm 25mm1 2.5 sq 1.5 sq mm armoured cable is design for areas mechanical damage and erosion.
So, the 10mm 16mm 25mm 2 core swa cable can laid in any way. For example, which is more suitable for direct laying in rock area. Usually, 2.5 sq mm 1.5 mm 6mm 25mm 16mm 2 core armoured cable is a fixed laying power cable. In other words, it is fixed in one place and basically immobile, power lines transmit electric energy. In addition to the above, the 10mm 16mm 25mm 2 core swa cable with armored layer. So it can also enhance the tensile strength, compress strength and other. Meanwhile it mechanical protection to extend the 2 core 4mm 25mm 10mm 1 2.5 sq 1.5 sq mm armoured cable service life.
What is the feature 2 core 4mm 25mm 10mm 1 2.5 sq 1.5 sq mm armoured cable?
Although, the 2.5 sq mm 1.5 mm 6mm 25mm 16mm 2 core armoured cable are belong to the small section area power 2 core swa cable. But, all them made of different conductors, for example, copper, tinned copper, aluminum, aluminium alloy etc.
But in metal bushings with insulating many materials such as, PVC XLPE PE etc. Which machine into flexible and solid combinations to the 2 core 10mm 1 2.5 sq 1.5 sq mm armoured cable. Because of 10mm 16mm 25mm 2 core swa cable is a power cable made up by assembling two or more electrical conductors. Generally it held the conductor of 6mm 25mm 2.5 sq mm 1.5 mm 16mm 2 core armoured cable together with an overall sheath. Meanwhile this 2 core 4mm 25mm 10mm 1 2.5 sq 1.5 sq mm armoured cable with high protective covering use in transmission of electrical power. Especially, the 2.5 mm 2 core 10mm 16mm 25mm 2 core swa cable for underground wiring needs.
Conductor: Aluminum or Copper
Armoured: SWA/STA/AWA/ATA
Insulation: PVC/XLPE
Cores: 2 core
Section Area: 1.5mm2-300mm2
Standard: IEC 60502, BS 7870, GB/T12706 or other.
Packaging: Iron Or Wooden Drum
What is the cause of short circuit of 10mm 25mm 2 core swa cable?
In order to fault rate of extension 6mm 2.5 sq mm 1.5 mm 6mm 25mm 2 core armoured cable is high. First of all, when the cable is connecting, the connection process of the end of the cable does not meet the quality requirements. Must comply with the 2 core 4mm 25mm 10mm 1 2.5 sq 1.5 sq mm armoured cable wiring process requirements, Especially pay attention to the insulation of the terminal. Do not allow moisture to enter key joints to avoid affecting insulation of the armored wire.
Secondly, the cracks in 10mm 16mm 25mm 2 core swa cable not well lappe, and lead-clad cracks enter the moisture. Especially in the weak connection of the end of the armored core cable, resulting in short circuit due to the breakdown of the insulation. Therefore you should pay attention to the cable bending radius should not be too small. So, It should be no less than 20 times the diameter of the 16mm 3 core armoured cable.