12kv 24kv single core n2xsy 1×35 1×50 1×240 1×185 1×35 xlpe pvc cable Structure
Tegangan: 6/10 (12) kV, 12/20 (24) kV, 18/30 (36) kV dan seterusnya.
Konduktor: Tembaga untuk kelas 2
Luas penampang: 35mm, 50mm, 70mm, 95mm, 120mm, 150mm, 185mm, 240mm, 300mm, 400mm, 630mm, dan seterusnya.
Inti: Inti tunggal
Isolasi: XLPE (Polietilena Tautan Silang)
Selubung luar: PVC
Warna selubung luar: merah
Tahan api: VDE 0482-332-1-2 / IEC 60332-1-2
Kemasan: drum besi dan kayu, atau lainnya.
Standar Nasional: DIN VDE 0276 dan DIN VDE 620
Application of 12kv 24kv single core n2xsy 1×50 1×240 1×185 1×35 xlpe pvc cable
Generally, medium voltage 12kv 24kv single core n2xsy 1×35 1×50 1×240 1×185 1×35 xlpe pvc cable for static application in ground outdoor.Such as in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.At the same tiem, 12kv 24kv single core n2xsy 1×50 1×240 1×185 1×35 xlpe pvc cable used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation. Due to along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.
The description of 12kv 24kv single core xlpe pvc n2xsy cable 1×50 1×240 1×185 1×35
We as well as known, the N2XSY cable is a single core copper conductor XLPE insulated and PVC sheath. So, n2xsy cable 1×50 1×240 1×185 1×35 suitable for indoor and outdoor static installation, directly in the ground or in cable ducts.
Oleh karena itu sebagai bagian dari jaringan distribusi tenaga listrik, stasiun trafo, blok switching dan pembangkit listrik. Sementara itu termasuk dalam sektor energi terbarukan. Terutama, kabel kabel N2XSEY dapat memadamkan sendiri dan tahan api untuk VDE 0482-332-1-2 dan IEC 60332-1.
single core copper n2xsy 1×35 1×50 1×240 1×185 1×35 1×630 xlpe pvc cable Parameter
Konduktor inti x penampang melintang |
Diameter konduktor | Ketebalan terisolasi | Diameter luar | Korsleting | Berat kabel | |
N x mm² | maks.mm | nominal mm | menit.
mm |
maks
.mm |
nominal A | prib.kg
/km |
1 x 35/16 | 07,5 | 3,4 | 23 | 28 | 5,00 | 892 |
1 x 50/16 | 08,6 | 3,4 | 24 | 29 | 7,15 | 1027 |
1 x 70/16 | 10,2 | 3,4 | 26 | 31 | 10,0 | 1254 |
1 x 95/16 | 12,0 | 3,4 | 27 | 32 | 13,6 | 1525 |
1 x 120/16 | 13,5 | 3,4 | 29 | 34 | 17,2 | 1773 |
1 x 150/16 | 15,0 | 3,4 | 30 | 35 | 21,4 | 2050 |
1 x 150/25 | 15,0 | 3,4 | 30 | 35 | 21,4 | 2135 |
1 x 185/16 | 16,8 | 3,4 | 32 | 37 | 26,5 | 2450 |
1 x 240/16 | 19,2 | 3,4 | 34 | 39 | 34,3 | 3000 |
1 x 240/25 | 19,2 | 3,4 | 34 | 39 | 34,3 | 3045 |
1 x 300/25 | 21,6 | 3,4 | 36 | 41 | 42,9 | 3646 |
1 x 630/35 | 31,5 | 3,4 | 48 | 52 | 90,1 | 7090 |
1 x 35/16 | 7,5 | 5,5 | 27 | 32 | 5,00 | 1067 |
1 x 50/16 | 8,6 | 5,5 | 28 | 33 | 7,15 | 1208 |
1 x 70/16 | 10,2 | 5,5 | 30 | 35 | 10,0 | 1446 |
1 x 95/16 | 12,0 | 5,5 | 31 | 36 | 13,6 | 1726 |
1 x 120/16 | 13,5 | 5,5 | 33 | 38 | 17,2 | 1983 |
1 x 150/16 | 15,0 | 5,5 | 34 | 39 | 21,4 | 2300 |
1 x 185/16 | 16,8 | 5,5 | 36 | 41 | 26,5 | 2650 |
1 x 185/25 | 16,8 | 5,5 | 36 | 41 | 26,5 | 2712 |
1 x 240/16 | 19,2 | 5,5 | 39 | 44 | 34,3 | 3250 |
1 x 240/25 | 19,2 | 5,5 | 39 | 44 | 34,3 | 3290 |
1 x 630/35 | 31,5 | 5,5 | 51 | 55 | 90,1 | 7340 |
1 x 50/16 | 8,6 | 8,0 | 33 | 38 | 7,15 | 1455 |
1 x 70/16 | 10,2 | 8,0 | 35 | 40 | 10,0 | 1706 |
1 x 95/16 | 12,0 | 8,0 | 36 | 41 | 13,6 | 2001 |
1 x 120/16 | 13,5 | 8,0 | 38 | 43 | 17,2 | 2270 |
1 x 150/25 | 15,0 | 8,0 | 39 | 44 | 21,4 | 2650 |
1 x 185/25 | 16,8 | 8,0 | 41 | 46 | 26,5 | 3022 |
1 x 240/25 | 19,2 | 8,0 | 43 | 48 | 34,3 | 3618 |
1 x 300/25 | 21,6 | 8,0 | 46 | 51 | 42,9 | 4350 |
1 x 630/35 | 31,5 | 8,0 | 57 | 62 | 90,1 | 4355 |