12kv 24kv single core copper n2xsy 1×35 1×50 1×240 1×185 1×35 1×630 xlpe pvc cable

12kv 24kv single core n2xsy 1×35 1×50 1×240 1×185 1×35 xlpe pvc cable Structure

xlpe pvc n2xsy 1x35 cable

Voltage: 6/10 (12)kV, 12/20 (24)kV, 18/30 (36)kV and so on.
Conductor: Copper for class 2
Cross-sectional area: 35mm, 50mm,70mm, 95mm, 120mm, 150mm, 185mm, 240mm,300mm, 400mm, 630mm and so on.
Cores: Single core
Insulation: XLPE (Cross-Linked Polyethylene)
Out sheath:PVC
Colour outer sheath: red
Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2
Packaging: iron and wooden drum, or other.
National Standard: both DIN VDE 0276 and DIN VDE 620

info@hdcarmouredcable.com

Application of 12kv 24kv single core n2xsy 1×50 1×240 1×185 1×35 xlpe pvc cable

Generally, medium voltage 12kv 24kv single core n2xsy 1×35 1×50 1×240 1×185 1×35 xlpe pvc cable for static application in ground outdoor.Such as in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.At the same tiem, 12kv 24kv single core n2xsy 1×50 1×240 1×185 1×35 xlpe pvc cable used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation. Due to along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

The description of 12kv 24kv single core xlpe pvc n2xsy cable 1×50 1×240 1×185 1×35

We as well as known, the N2XSY cable is a single core copper conductor XLPE insulated and PVC sheath. So, n2xsy cable 1×50 1×240 1×185 1×35 suitable for indoor and outdoor static installation, directly in the ground or in cable ducts.

medium voltage n2xsy 1x35 1x50 1x185

info@hdcarmouredcable.com

Therefore as part of power distribution networks, transformer stations, switching blocks and power plants. Meanwhile it including in the renewable energy sector. Especially, The N2XSEY cable cable is self-extinguishing and flame retardant to VDE 0482-332-1-2 and IEC 60332-1.

single core copper n2xsy 1×35 1×50 1×240 1×185 1×35 1×630 xlpe pvc cable Parameter

Core x conductor
cross-section
Conductor diameter Insulated thickness External diameter Short circuit Cable weight
N x mm² max.mm nominal mm min.

mm

max

.mm

nominal A prib.kg

/km

1 x 35/16 07,5 3,4 23 28 5,00 892
1 x 50/16 08,6 3,4 24 29 7,15 1027
1 x 70/16 10,2 3,4 26 31 10,0 1254
1 x 95/16 12,0 3,4 27 32 13,6 1525
1 x 120/16 13,5 3,4 29 34 17,2 1773
1 x 150/16 15,0 3,4 30 35 21,4 2050
1 x 150/25 15,0 3,4 30 35 21,4 2135
1 x 185/16 16,8 3,4 32 37 26,5 2450
1 x 240/16 19,2 3,4 34 39 34,3 3000
1 x 240/25 19,2 3,4 34 39 34,3 3045
1 x 300/25 21,6 3,4 36 41 42,9 3646
1 x 630/35 31,5 3,4 48 52 90,1 7090
1 x 35/16 7,5 5,5 27 32 5,00 1067
1 x 50/16 8,6 5,5 28 33 7,15 1208
1 x 70/16 10,2 5,5 30 35 10,0 1446
1 x 95/16 12,0 5,5 31 36 13,6 1726
1 x 120/16 13,5 5,5 33 38 17,2 1983
1 x 150/16 15,0 5,5 34 39 21,4 2300
1 x 185/16 16,8 5,5 36 41 26,5 2650
1 x 185/25 16,8 5,5 36 41 26,5 2712
1 x 240/16 19,2 5,5 39 44 34,3 3250
1 x 240/25 19,2 5,5 39 44 34,3 3290
1 x 630/35 31,5 5,5 51 55 90,1 7340
1 x 50/16 8,6 8,0 33 38 7,15 1455
1 x 70/16 10,2 8,0 35 40 10,0 1706
1 x 95/16 12,0 8,0 36 41 13,6 2001
1 x 120/16 13,5 8,0 38 43 17,2 2270
1 x 150/25 15,0 8,0 39 44 21,4 2650
1 x 185/25 16,8 8,0 41 46 26,5 3022
1 x 240/25 19,2 8,0 43 48 34,3 3618
1 x 300/25 21,6 8,0 46 51 42,9 4350
1 x 630/35 31,5 8,0 57 62 90,1 4355

info@hdcarmouredcable.com

12/20 kV cable 1×50 1×240 1×185 1×35

lxpe pvc n2xsy cable 1x240

    Leave your message, Get free quote

    Let's together work as for your project by E-mail: info@hdcarmouredcable.com

    * Your Name

    * Your Email

    Your Country

    * Your Requirement

    en_USEnglish